Stucco Trouble Shooting- Cause and Cure

The following table was first published by the SMA and been recently updated. The SMA offers this as a general troubleshooting guide of problems or unwanted conditions found or related to portland cement plaster/stucco walls. The chart lists the conditions, possible causes, prevention’s or possible remedies. Not all of these conditions are in the control of the plastering contractor. This chart can also be used as a pre-installation discussion guide for plaster/stucco projects to help avoid unwanted conditions\

Stucco Manufacturers
PORTLAND PLASTER CEMENT
TROUBLESHOOTING – CAUSE AND CURE
CONDITION CAUSE PREVENTION OR POSSIBLE REMEDY
Cement fails to setDo not use old cement, shelf life is typically
one year.
Excessive aggregateMeasure aggregate (calibrated box) to establish
proper shovel count or use pre-blended mix.
Inadequate damp curingKeep damp for 24 hours. Fresh soft plaster
may be redeemed by continuous wetting until
proper set and hardness are obtained.
Inadequate or excessive mixingAfter all materials are in the mixer, minimum
two (2) but not more than ten (10) minutes.
SOFT PLASTERImpurities in water or aggregateTest water and aggregate. Use washed plaster
sand